Publication:
An Experimental Analysis and Validation of Electrical Impedance Tomography Technique for Medical or Industrial Application

dc.contributor.affiliationDA-IICT, Gandhinagar
dc.contributor.authorKumar, Ramesh
dc.contributor.authorKumar, Sharvan
dc.contributor.authorSengupta, Amit
dc.date.accessioned2025-08-01T13:09:10Z
dc.date.issued13-03-2019
dc.description.abstractElectrical impedance tomography is a recently established technique by which impedance of an object (medical or nonmedical applications) is measured data from the surface of the object, and a numerically simulated reconstruction of the object internal shape of the image can be obtained. This imaging technique based on boundary or surface voltage is measured when the different current pattern is injected into it. For current pulse, we are creating a voltage controlled current source, which is based on the different RC circuits, according to current amplitude and frequency values. The current source used in inject the current pulse of the various phantoms. The current position and measuring voltage is controlled by the created control unit or programmable system on chip (PSOC) of the proposed EIT system. After that image reconstruction of the cross-sectional image of resistivity requires sufficient data collection from used phantoms, which is based on finite element method (FEM) method and Tikhonov regularization method with helps of graphical user interface (GUI) on MatLab. The objective of the GUI was to produce an image (2D/3D), impedance distribution graph, and the FEM mesh model according to used electrode combinations from the various phantoms. EIT system has a great potential for imaging modality, is non-invasive, radiation-free, and inexpensive for medical applications.
dc.identifier.citationKumar, Ramesh, Kumar, Sharvan, and Sengupta, Amit "An Experimental Analysis and Validation of Electrical Impedance Tomography Technique for Medical or Industrial Application," Biomedical Engineering: Applications, Basis and Communications, vol. 31, no. 2, 13 Mar. 2019, pp. 1950010-1-1950010-17. Doi: 10.4015/S1016237219500108
dc.identifier.doi10.4015/S1016237219500108
dc.identifier.issn1793-7132
dc.identifier.scopus2-s2.0-85062902095
dc.identifier.urihttps://ir.daiict.ac.in/handle/dau.ir/1698
dc.language.isoen
dc.publisherWorld Scientific
dc.relation.ispartofseriesVol. 31; No. 2
dc.source Biomedical Engineering: Applications, Basis and Communications
dc.source.urihttps://www.worldscientific.com/doi/abs/10.4015/S1016237219500108
dc.titleAn Experimental Analysis and Validation of Electrical Impedance Tomography Technique for Medical or Industrial Application
dspace.entity.typePublication
relation.isAuthorOfPublication019450b4-4a0a-4606-9919-e5eae28dce11
relation.isAuthorOfPublication.latestForDiscovery019450b4-4a0a-4606-9919-e5eae28dce11